Fire Sprinkler Valve Tags
Engraved red and white control valve tags for sprinkler risers, PIVs, zone valves, and standpipes. Permanent legends cut into UL-approved 2-ply acrylic that will not corrode in a riser room the way brass and stamped tags do.
Round and square hanging tags shown with a 3/16" chain bore
Tags that survive the riser room
Fire protection valves live in wet, humid, unconditioned spaces, and outdoors on post indicator valves. Stamped brass dulls and the legend fills in. Printed tags curl and fade. Either way the annual NFPA 25 inspection turns into guesswork about which valve controls what.
An engraved acrylic tag carries the legend in the material. The red cap layer is cut away to expose the white core, so the contrast is structural, not printed. It does not corrode, there is no printed surface to peel or wear off, and it holds the red fire protection color that metal tags cannot.
Same stock as our mechanical valve tags, custom valve tags and equipment labels, so a facility can tag fire protection, plumbing, and process valves in one order with one numbering scheme. Need fire pump controller and disconnect identification too? Those come off the same engraved panel label line.
Fire valve tag specifications
Material | Rowmark DurMark rigid 2-ply acrylic, 1/16" thick
Certification | UL Yellowcard E354751, UL94-HB flame rated
Shapes | Round or square hanging tags, or flat wall plates
Text height | 1/4" to 1", up to six lines per tag
Colors | Red/white standard, seven standard combinations stocked
Mounting | Drilled bore for chain or wire, screw holes, or 3M adhesive
Production | 1-2 business days, made in Clayton, NC
What gets tagged on a water based system
OS&Y and butterfly control valves
Valve number, system served, and normal position on a hanging tag an inspector can read from the floor.
Post indicator valves
Outdoor PIV identification that stays legible through UV, rain, and freeze cycles.
Riser and zone control assemblies
Riser number, floor, and zone served, tagged so the annual NFPA 25 inspection moves fast.
Inspector test and drain valves
Test and drain identification at each zone so nobody trips the wrong valve.
Fire department connections
FDC service plates showing the system supplied and required pressure.
Standpipe and hose valves
Floor and zone identification on standpipe outlets and hose valve stations.
Wording and required content vary by jurisdiction. Check your local authority having jurisdiction before finalizing a set, and send us the approved format. We engrave exactly what you specify.
Fire sprinkler valve tag FAQ
What does NFPA 25 require on a fire sprinkler valve tag?
NFPA 25 requires that each control valve in a water based fire protection system be identified with a sign showing the valve and the portion of the system it controls. In practice that means the valve number, the service or system, and the area served, hung so an inspector can read it from the floor. Confirm the exact wording with your local authority having jurisdiction, since jurisdictions add requirements.
What color should fire protection valve tags be?
Red with white lettering is the convention for fire protection service, and it lines up with ANSI Z535 fire equipment identification. We stock red/white along with six other combinations if your AHJ or facility standard calls for something different.
Are these metal or brass tags?
They are engraved two ply acrylic, not brass or aluminum. We do not supply brass tags. Acrylic will not corrode in a riser room or a wet pipe environment, it can carry the red fire protection color that brass cannot, and the legend is cut into the material instead of stamped on the surface.
Will the tag hold up in a riser room or outdoors?
Rowmark DurMark acrylic is UV stable and listed for exterior use. Check it against your location and spec. Because the legend is engraved through the cap layer to a contrasting core, there is no printed surface to peel or wear off in a PIV or wall hydrant location.
How do the tags attach to the valve?
Standard tags include a drilled bore for beaded chain, wire, or a zip tie. Tell us the bore size and location and we will match it. Screw holes and 3M adhesive backing are available when the tag mounts to a wall or a riser plate instead of hanging.
Can you engrave a full numbered set for a building?
Yes. Send your valve schedule as a spreadsheet and we engrave the whole set, including sequential numbers, prefixes, and the area each valve serves. Large multi building sets are routine.
Can I put my own wording on the tags?
Yes. Every tag is made to order with your exact text, shape, size, and color combination. Lay it out in the custom label designer and see live pricing before you order.
Tag a whole building in one order
Upload your valve schedule, get instant pricing, ship in 1-2 days.